8/31/2023 0 Comments Fire inspectionWithin 6ĥ F-6 Egress Lighting Inspection, testing, and maintenance for the emergency lighting system were not in accordance with The ACCORD standard. Provide automatic smoke detectors throughout the building in accordance with NFAP72. Smoke alarm activation sounds only a local alarm and does not provide automatic fire alarm notification of occupants. F-5 The building is equipped with single-station smoke alarms. Inspect, test and maintain the fire alarm system, and keep written records on-site, in accordance with NFPA 72. Design within 4, install within 9 F-4 Inspection, testing, and maintenance for the fire alarm system were not in accordance with NFPA72. Replace the fire alarm system with a new, listed addressable fire alarm system in accordance with NFPA 72. ImmediateĤ F-3 The fire alarm system is antiquated, not a listed system, and does not provide alarm and notification features consistent with acceptable standards. If locks are required for security reasons, utilize special door locking features complying with NFPA 101. Remove locking features from all egress doors. F-2 Egress Egress doors with locking features are provided at building exits. Provide dedicated storage rooms separated by minimum 1-hr fire-rated construction. Category Finding Recommendation Remediation Timeframe F-1 Fire Rated Construction Store room used for combustible storage are not separated by firerated construction. Findings And Recommendations - Sewing Shed No. ![]() The specific timing of improvements, including any requested extensions due to design / installation constraints, shall be submitted to the Accord for approval.ģ Table 1. An implementation schedule shall be developed by the factory to remediate each of the findings. Recommendations have been provided to address each issue. Tables 1-3 summarizes the major fire safety issues identified during the inspection. The inspection did not include identification of minor deficiencies, which will be further addressed as part of follow-up inspections. The scope of this initial fire safety inspection was limited to the review and identification of major fire safety issues. The purpose of this survey was to identify significant fire safety issues and to provide recommendations for remediation based on applicable standards specified by the Accord. This summary identifies the major deficiencies that were identified during the inspection. ![]() ![]() 1 FIRE SAFETY INSPECTION REPORT M.I.T APPARELS LTD PATHANTULY, GODNAIL, SHIDDIRGONJ, NARAYANGONJ OTHER FACTORIES: NONE June 4, 2014Ģ SUMMARY was surveyed for fire safety on by Hughes Associates, Inc.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |